Fieldbus Converters
Protocol and Fieldbus Converters
With fieldbus converters PLC and automation systems of different manufacturers can communicate with each other. Typical application is connecting a CANopen actuator to a Profibus factory bus.
Via protocol converters different actuators and I/O units can be connected to various manufacturers' automation systems. Typical production application is a machine in EtherCAT system communicating with a process automation system in Profinet network.
Shop By
-
Fieldbus to IoT GatewayPrice
HMS AB7570-F
Anybus X-gateway IIoT-PROFINET IRT Slave- Protocol: Profinet
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
800,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7566-F
Anybus X-gateway IIoT-Interbus copper Slave- Protocol: Interbus
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
1 666,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7564-F
Anybus X-gateway IIoT-ControlNet Slave- Protocol: ControlNet
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
1 409,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7562-F
Anybus X-gateway IIoT-CC-Link Slave- Protocol: CC-Link
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
800,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7561-F
Anybus X-gateway IIoT-Modbus RTU Slave- Protocol: Modbus RTU
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
800,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7559-F
Anybus X-gateway IIoT-DeviceNet Slave- Protocol: DeviceNet
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
677,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7558-F
Anybus X-gateway IIoT-PROFIBUS DP-V0 Slave- Protocol: Profibus
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
800,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7557-F
Anybus X-gateway CC-Link IE Field Slave - IIoT- Protocol: CC-Link
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
800,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7555-F
Anybus X-gateway Modbus TCP Slave - IIoT- Protocol: Modbus/TCP
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
800,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7554-F
Anybus X-gateway Ethernet/IP Slave - IIoT- Protocol: EtherNet/IP
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
677,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7560-F
Anybus X-gateway IIoT-CANopen Slave- Protocol: CANopen
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
800,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7556-F
Anybus X-gateway IIoT-EtherCAT Slave- Protocol: EtherCAT
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
800,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7553-F
Anybus X-gateway Ethernet/IP Master - IIoT- Protocol: EtherNet/IP
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
1 128,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7551-F
Anybus X-gateway DeviceNet Master - IIoT- Protocol: DeviceNet
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
1 128,00 € -
Fieldbus to IoT GatewayPrice
HMS AB7550-F
Anybus X-gateway PROFIBUS DP-V1 Master - IIoT- Protocol: Profibus
- Protocol 2: MQTT, OPC UA
- Input voltage: 9-36 Vdc
- Oper. temperature -25...60 °C
954,00 € -
Fieldbus to IoT GatewayPrice
HMS AB9079-C
Anybus EtherCAT to .NET Bridge- Protocol: EtherCAT
- Protocol 2: .NET
- Input voltage: 9-36 Vdc
- Oper. temperature -25...70 °C
798,00 € -
Fieldbus to IoT GatewayPrice
HMS AB9078-C
Anybus Ethernet/IP to .NET Bridge- Protocol: EtherNet/IP
- Protocol 2: .NET
- Input voltage: 9-36 Vdc
- Oper. temperature -25...70 °C
943,00 € -
Fieldbus to IoT GatewayPrice
HMS AB9077-C
Anybus PROFINET to .NET Bridge- Protocol: Profinet
- Protocol 2: .NET
- Input voltage: 9-36 Vdc
- Oper. temperature -25...70 °C
798,00 € -
Fieldbus to IoT GatewayPrice
HMS AB9071-C
Anybus PROFIBUS to .NET Bridge- Protocol: Profibus
- Protocol 2: .NET
- Input voltage: 9-36 Vdc
- Oper. temperature -25...70 °C
798,00 € -
Fieldbus to IoT GatewayPrice
Advantech WISE-710-N600A
NXP Cortext A9, 2xLAN, 3xCOM, 4DI/DO, 8G eMMC- Input voltage: 24-24 Vdc
- Oper. temperature -20...55 °C
387,00 €